Procedure
Scope: Cyclotron
Type: Informal
Last Reviewed: Needs Review
References: Citation Needed
Contents
Description
Perform a controlled access into the cyclotron upper vault from the E-Hall/Cyclotron maze.
Required Equipment
- DRD
- RAM
- Contamination meter
- Active work permit
Summary
- Define cyclotron and E-Linac off
- Wait 30 minutes for air activation
- If necessary, pin residual monitor 06 "Upper South East Vault" to allow for vault key release
- Obtain the "EHall Door" key from the E-Hall ASU
- Obtain the "Ehall/Cyc Maze South door" key from the E-Hall ASU
- Obtain the "e-HALL/CYC MAZE NORTH" key from the vault and service annex ASU
- Open "EHall Door" and access the E-Hall
- Open "e-HALL/CYC MAZE NORTH" and access the E-Hall/Cyc Maze
- Perform controlled access through "Ehall/Cyc Maze South door" into upper vault
- Check all personnel for contamination
- Lockup E-Hall/Cyc Maze
- Lockup E-Hall
- Secure upper vault